Respo gif

SP-MGTP

Portable Multi-Gas Detector

The SP-MGTP is a sampling-type multi-gas detector capable of monitoring up to 6 gases with 37 possible gas combinations, including Volatile Organic Compounds (VOC). It continuously detects oxygen (O₂), toxic, flammable gases, and VOCs, providing real-time alerts through LED indicators, sound alarms, and vibration signals. Designed to prevent industrial accidents caused by hazardous gas exposure, this device offers reliable protection in demanding environments.

KEY FEATURES

  • Multi-gas Detection for Comprehensive Monitoring: Detects up to 6 gases with 37 possible combinations, offering versatile applications for monitoring a wide range of industrial environments.
  • Sampling Type with Embedded Pump & Probe: Ensures accurate and reliable gas sampling for continuous monitoring in diverse environments.
  • Real-time Monitoring for Immediate Results: Provides continuous gas concentration readings, delivering immediate feedback on environmental conditions.
  • Water and Dustproof (IP67 Rating): Designed to endure rugged environments, offering reliable performance in harsh conditions.
  • High-performance Alarms: Includes visual, audible, and vibrating alarms to immediately alert users to hazardous gas levels.
  • Event Log for Easy Tracking: Automatically records recent events, including bump tests and calibrations, allowing for efficient tracking and maintenance.
  • IrDA Communication: Simplifies configuration and data management with infrared communication.
  • Single Docking Station: Provides a convenient docking station for easy bump testing and calibration, improving operational efficiency.
  • Explosion-proof Certification: Complies with global explosion-proof standards, ensuring safe use in hazardous environments worldwide.
  • Pump Blockage Alarm: Alerts users to any pump blockage, maintaining consistent and reliable operation.
  • Filter Contamination Check: Enables users to visually inspect the filter status, ensuring proper operation and maintenance.
  • Three-button Operation: The device features three intuitive buttons for easy and convenient operation.

DESCRIPTION

The SP-MGTP is a sampling-type multi-gas detector designed to monitor up to six gases simultaneously. It is specifically engineered to detect the gases most commonly associated with industrial accidents, including those that cause oxygen deficiency, toxic gas poisoning, and the risk of gas explosions. This device can monitor up to six gases with 37 possible combinations of toxic and flammable gases. The concentrations of these gases are continuously displayed, and the detector activates visual, audible, and vibrating alarms when dangerous levels are detected, ensuring immediate alerts for safety.

KEY FEATURES

  • Multi-gas Detection for Comprehensive Monitoring: Detects up to 6 gases with 37 possible combinations, offering versatile applications for monitoring a wide range of industrial environments.
  • Sampling Type with Embedded Pump & Probe: Ensures accurate and reliable gas sampling for continuous monitoring in diverse environments.
  • Real-time Monitoring for Immediate Results: Provides continuous gas concentration readings, delivering immediate feedback on environmental conditions.
  • Water and Dustproof (IP67 Rating): Designed to endure rugged environments, offering reliable performance in harsh conditions.
  • High-performance Alarms: Includes visual, audible, and vibrating alarms to immediately alert users to hazardous gas levels.
  • Event Log for Easy Tracking: Automatically records recent events, including bump tests and calibrations, allowing for efficient tracking and maintenance.
  • IrDA Communication: Simplifies configuration and data management with infrared communication.
  • Single Docking Station: Provides a convenient docking station for easy bump testing and calibration, improving operational efficiency.
  • Explosion-proof Certification: Complies with global explosion-proof standards, ensuring safe use in hazardous environments worldwide.
  • Pump Blockage Alarm: Alerts users to any pump blockage, maintaining consistent and reliable operation.
  • Filter Contamination Check: Enables users to visually inspect the filter status, ensuring proper operation and maintenance.
  • Three-button Operation: The device features three intuitive buttons for easy and convenient operation.

DIMENSION

Product Specifications

Specification Details
Model SP-MGTP
Display LCD display with backlight for clear visibility in various lighting conditions
Indicator LEDs for status and alarm notifications
Keys 3 operational and programming keys for intuitive navigation and setup
Sensors Electrochemical Sensors: For toxic gases and oxygen (O₂) detection
PID (Photoionization Detector): For precise VOC (Volatile Organic Compound) detection
Catalytic Sensors: For combustible gas detection
NDIR (Non-Dispersive Infrared) Sensors: For monitoring combustible gases
Alarms Visual: LCD alarm display with backlight and indicator LEDs for clear alerts
Audible: 90 dB buzzer at 10 cm for immediate sound warnings
Vibration: Vibration alert for hazardous gas detection
Dimensions 77 mm (W) x 146 mm (H) x 43 mm (D)
Weight 490 g
Mounting Method Integrated belt clip for easy attachment and hands-free use
Operating Temperature Range -20°C to +50°C
Operating Humidity Range 10% to 90% RH (Non-condensing)
IP Rating IP67 (Fully dustproof and water-resistant for enhanced durability in harsh environments)
Environment Pressure Range 80 kPa to 120 kPa (Suitable for use in environments with this pressure range)
Sampling Type Built-in pump for efficient and accurate gas sampling
Sampling Distance: 25m
Battery Type Rechargeable Li-ion power supply (4,000 mAh) for extended operational time
Operating Time SP-MGTP-P0 Series: Approximately 30 hours of continuous use
SP-MGTP-N0/N1/N2 Series: Up to 5 days or more, depending on usage and settings
Enclosure Material TPU-coated polycarbonate (PC) for enhanced durability in tough conditions
IR-Link For seamless data management and easy configuration
Flow Rate 250 to 300 cc/min for consistent and accurate gas sampling
Warranty 2 years from the date of purchase

Sensor Specifications

The SP-MGTP is equipped with four sensor slots, providing versatile and customizable gas detection capabilities. This modular design allows for the combination of different gas sensors to meet specific monitoring requirements. Below is a detailed list of the available sensors for each slot, enabling a wide range of configurations tailored to diverse industrial and safety applications.

Model Name Slot 1 (Fixed) Slot 2 (Fixed) Slot 3 (Optional Gas 1) Slot 4 (Optional Gas 2)
SP-MGTP-P-4 O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) -
SP-MGTP-P-5-PID O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) PID (VOC Detection)
SP-MGTP-P-5-SO₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) SO₂ (Sulfur Dioxide)
SP-MGTP-P-5-Cl₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) Cl₂ (Chlorine)
SP-MGTP-P-5-NH₃ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) NH₃ (Ammonia)
SP-MGTP-P-5-H₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) H₂ (Hydrogen)
SP-MGTP-P-5-NO₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) NO₂ (Nitrogen Dioxide)
SP-MGTP-P-5-HF O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) HF (Hydrogen Fluoride)
SP-MGTP-P-5-HCN O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) HCN (Hydrogen Cyanide)
SP-MGTP-P-5-HCl O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) HCl (Hydrochloric Acid)
SP-MGTP-P-5-NO O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) NO (Nitric Oxide)
SP-MGTP-P-5-H₂O₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (Catalytic) H₂O₂ (Hydrogen Peroxide)
SP-MGTP-N-4 O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) -
SP-MGTP-N-5-PID O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) PID (VOC Detection)
SP-MGTP-N-5-SO₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) SO₂ (Sulfur Dioxide)
SP-MGTP-N-5-Cl₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) Cl₂ (Chlorine)
SP-MGTP-N-5-NH₃ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) NH₃ (Ammonia)
SP-MGTP-N-5-H₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) H₂ (Hydrogen)
SP-MGTP-N-5-NO₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) NO₂ (Nitrogen Dioxide)
SP-MGTP-N-5-HF O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) HF (Hydrogen Fluoride)
SP-MGTP-N-5-HCN O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) HCN (Hydrogen Cyanide)
SP-MGTP-N-5-HCl O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) HCl (Hydrochloric Acid)
SP-MGTP-N-5-NO O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) NO (Nitric Oxide)
SP-MGTP-N-5-H₂O₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CH₄ (IR) H₂O₂ (Hydrogen Peroxide)
SP-MGTP-N-5-CO₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) -
SP-MGTP-N-6-PID O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) PID (VOC Detection)
SP-MGTP-N-6-SO₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) SO₂ (Sulfur Dioxide)
SP-MGTP-N-6-Cl₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) Cl₂ (Chlorine)
SP-MGTP-N-6-NH₃ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) NH₃ (Ammonia)
SP-MGTP-N-6-H₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) H₂ (Hydrogen)
SP-MGTP-N-6-NO₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) NO₂ (Nitrogen Dioxide)
SP-MGTP-N-6-HF O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) HF (Hydrogen Fluoride)
SP-MGTP-N-6-HCN O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) HCN (Hydrogen Cyanide)
SP-MGTP-N-6-HCl O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) HCl (Hydrochloric Acid)
SP-MGTP-N-6-NO O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) NO (Nitric Oxide)
SP-MGTP-N-6-H₂O₂ O₂ (Oxygen) CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) CO₂ (IR) + CH₄ (IR) H₂O₂ (Hydrogen Peroxide)

Applicable Sensor Specifications

The SP-MGTP ioffers a wide range of gas sensors, each designed to meet specific detection needs across various environments. Each sensor is engineered with distinct measuring ranges, resolutions, and alarm thresholds to provide reliable and accurate detection. Below are the specifications for the available sensors:

Gas Sensor Type Measuring Range Resolution Low Alarm High Alarm
Oxygen (O₂) Electrochemical 0 ~ 30 %vol 0.1 %vol 19 %vol 23 %vol
Carbon Monoxide (CO) Electrochemical 0 ~ 1000 ppm 1 ppm 30 ppm 60 ppm
Hydrogen Sulfide (H₂S) Electrochemical 0 ~ 200 ppm 0.1 ppm 10 ppm 15 ppm
Methane (CH₄) Catalytic / NDIR 0 ~ 100 %LEL 1 %LEL 10 %LEL 30 %LEL
Carbon Dioxide (CO₂) Non-Dispersive Infrared (NDIR) 0 ~ 5 %vol 0.01 %vol 0.5 %vol 1.0 %vol
Ammonia (NH₃) Electrochemical 0 ~ 100 ppm 1 ppm 25 ppm 35 ppm
Sulfur Dioxide (SO₂) Electrochemical 0 ~ 20 ppm 0.1 ppm 2 ppm 5 ppm
Hydrogen (H₂) Electrochemical 0 ~ 1000 ppm 1 ppm 100 ppm 500 ppm
Nitrogen Dioxide (NO₂) Electrochemical 0 ~ 20 ppm 0.1 ppm 3 ppm 5 ppm
Chlorine (Cl₂) Electrochemical 0 ~ 20 ppm 0.1 ppm 0.5 ppm 1 ppm
Hydrogen Fluoride (HF) Electrochemical 0 ~ 10 ppm 0.1 ppm 0.5 ppm 1.0 ppm
Hydrogen Cyanide (HCN) Electrochemical 0 ~ 50 ppm 0.1 ppm 10 ppm 20 ppm
Hydrogen Chloride (HCl) Electrochemical 0 ~ 50 ppm 0.1 ppm 5 ppm 10 ppm
VOC (PID) Photoionization Detector (PID) 0 ~ 4000 ppm 1 ppm 50 ppm 200 ppm
Nitric Oxide (NO) Electrochemical 0 ~ 500 ppm 0.5 ppm
Hydrogen Peroxide (H₂O₂) Electrochemical 0 ~ 100 ppm 0.1 ppm

Voc gas Detector