Respo gif

BS-03 is an Infrared Sensor Technology based type gas detector

The BS-03 is an Infrared Sensor Technology based type gas detector with smart transmitter, The sensor is integrated to the transmitter having digital LCD-LED display This detec- tor uses high-performance infrared components and micro-control technology, combined with sophisticated SMD process manufacturing, It has good repeatability, temperature and humidity characteristics, as well as long service life and convenient operation.

The output signal of the detector is 4~20mA standard signal with optional HART.

Besides Infrared Sensor the BS-03 is also available with Plug in SMART Sensors for Point Infrared, VOC's, Toxic's, Oxygen and Catalytic Combustion, These sensors are replaceable type and can be replaced without any special tools.

Features & benefits

Infra-Red Sensor

Double beam infrared technology, dual compensated, Non-Dispersive IR (NDIR) with temperature compen- sation for excellent stability and minimal drift

Output Choice

  • 4-20mA
  • RS-485
  • HART over 4-20mA (Optional)

Digital Display

  • LED-LCD Display
  • No Backlight Required
  • Can be seen from Wide Distance

Optics

  • Heated Optics NDIR Sensor
  • Dirty Optics warning with correct Operation upto 70-80% for NDIR Sensor
  • Easy Cleaning of Mirror or Sensor Replacement

Other Features

  • Relay outputs for Alarm and Faults
  • Non-Instrusive Calibration
  • Intrinsically Safe HART Port (Optional)
  • Smart Sensor modules for Point IR, Toxics and VOC's

Specifications

Dimensions 210mm x 200mm x 105mm
Weight < 2 Kg Aluminium / < 6 Kg SS-316
Enclosure Material Cast Aluminium Alloy or SS-316
Sensor Housing Material SS-316
Ingress Protection IP-66
Cable Entry Two 1/2" NPT
Power 18-30VDC < 8W (Sensor with Heated Optics) else < 3W
Electrical Output 4-20mA Current Sink or Source, RS-485 MODBUS RTU, HART over 4-20mA Signal
Display Main Display: LED-LCD (Red)
Indicators: Alarm 1, Alarm 2, Fault
Relays 2 Configurable Relays (Optional 3 LOW, HI H, FAULT)
5A@230VAC, 5A@30VDC
Intrinsically Safe HART Port Optional
Sampling Method Natural Diffusion with Chimney Effect
Working Temperature -40°C to +70°C
Working Humidity 0~95% RH (no dews)
Accuracy ± 1% for 0-100% range (NDIR)
± 1% to ± 2% for 0-100% range (TOXICS) (Depending on Gas)
Repeatability ± 2% FSD
Warm-up Time NDIR/Catalytic - 120 seconds
Toxics - 60 seconds
Zero Drift ± 2% FSD per year maximum
Approvals ATEX - Ex dB IIC T6 b, PESO
Testing EN 60079-0: 2012, EN 50270:2015
EN 60079-1: 2014, EN IEC 60079-0:2018, EN 60079-1:2014
SIL2, EN 60079-29-1:2016, EN 60079-2:2015

Sensor Range

Target Gas Range Resolution Sensor Type Response Time (T90)
CH₄0–100% LEL1% LELCatalytic Combustion / Non-Dispersive IR≤30 sec (Cat), ≤3 sec (NDIR)
0–5% VOL0.01% VOLNon-Dispersive IR≤3 sec
0–100% VOL1% VOLNon-Dispersive IR≤3 sec
C₃H₈0–100% LEL1% LELCatalytic Combustion / Non-Dispersive IR≤30 sec (Cat), ≤3 sec (NDIR)
H₂0–100% LEL1% LELCatalytic Combustion≤15 sec
0–1000 ppm1 ppmElectrochemical≤10 sec
CO₂0–5% VOL0.01% VOLNon-Dispersive IR≤3 sec
0–6000 ppm1 ppmNon-Dispersive IR≤3 sec
C₄H₁₀0–100% LEL1% LELCatalytic Combustion / Non-Dispersive IR≤30 sec (Cat), ≤3 sec (NDIR)
CO0–2000 ppm1 ppmElectrochemical≤10 sec
0–1000 ppm1 ppmElectrochemical≤10 sec
0–500 ppm1 ppmElectrochemical≤10 sec
H₂S0–100 ppm1 ppmElectrochemical≤10 sec
0–30 ppm1 ppmElectrochemical≤10 sec
0–20 ppm1 ppmElectrochemical≤10 sec
O₂0–30% VOL0.1% VOLElectrochemical≤10 sec
NH₃0–100 ppm1 ppmElectrochemical≤10 sec
0–1000 ppm1 ppmElectrochemical≤10 sec
SO₂0–100 ppm1 ppmElectrochemical≤10 sec
Cl₂0–20 ppm0.1 ppmElectrochemical≤10 sec
VOC0–1000 ppm1 ppmPID≤10 sec
NO₂0–10 ppm1 ppmElectrochemical≤10 sec
ETO0–100 ppm1 ppmElectrochemical≤10 sec
HCN0–100 ppm1 ppmElectrochemical≤10 sec

Note: Specification can change according to the customer requirements.

BS 03 Certified

Voc gas Detector

Area Gas Detector