The new XgardIQ, our most intelligent fixed-point gas detector, increases safety by minimising the time operators must spend hazardous areas.
This versatile transmitter and gas detector has a range of features that protect engineers and support facilities managers of oil, gas, chemical & petrochemical plants to name a few.
Available fitted with a variety of flammable, toxic or oxygen gas sensors.
Overview
XgardIQ is an intelligent and versatile gas detector and transmitter compatible with Crowcon's full range of sensor technologies. Available fitted with a variety of flammable, toxic or oxygen gas sensors.
Providing analogue 4-20mA and RS-485 Modbus signals as standard, XgardIQ is optionally available with Alarm and Fault relays and HART communications. The 316 stainless steel are available with three M20 or 1/2"NPT cable entries.
Easy and safe to use
- OLED display - Bright, clear display indicates gas level and detector status even in dark locations
- Non-intrusive calibration - Zero and calibration functions are performed via the display and keypad, without the need for a hot-work permit or any special tools (e.g. no magnetic wand required)
- +ve Safety indicator - Confirms the detector is operating safely at a glance
- Event log function - Stores all alarm, fault and maintenance events to provide a history of detector use
Simple installation and maintenance
- Universal transmitter - Common transmitter for Crowcon's full range of sensor technologies
- Hot-swap sensor modules - Sensors can easily be replaced using one hand without requiring tools or a hot-work permit
- Auto-sense function - Automatically detects whether the control system is 4-20mA current sink or source and sets itself appropriately, eliminating the risk of being incorrectly set
- Auto-configure function - Detects when a sensor module is plugged-in and uploads the appropriate gas type, range, units and alarm levels
Reliability
- Smart Bump and Speedy Bump test functions - Enable sensor health and response to be verified quickly and easily using test gas. Process is automated and provides a reminder when a bump test is due
- Calibration due warning - Reminds the user when calibration is due to ensure that sensors remain operational and accurate at all times
- Sensor range selection - User can set the full-scale range of the sensor via the display menu according to site or specific location requirements
Specifications
Size |
H278 x W140 x D89mm (10.9 x 5.5 x 3.5 in) |
Weight |
4.1Kg (9lbs) |
Enclosure material |
316 stainless steel |
Ingress protection |
IP66 |
Connection |
Three M20 or ½”NPT cable gland entries.Certified, removable plugs are fitted to left-hand and lower righthand entries |
Power |
14-30 VDC. <4W |
Display |
Main display - OLED 128 x 64 pixels, yellow text on black background
Indicators - Amber, Red and Green LED’s for detector status; Blue +ve Safety LED |
Electrical output |
4-20mA current sink or source (Auto-Sense or manual selection); warning and fault signals are configurable. NAMUR NE 43 compliant
RS-485 Modbus RTU
HART 7 over 4-20mA signal and via local I.S. test points (optional)
Foundation Fieldbus (option pending, contact Crowcon)
Relays (optional)
Alarm 1, Alarm 2, Fault
SPCO contacts rated 5A, 230Vac
Relay configuration options
Energised or de-energised
Latching or non-latching
Rising or falling
Configurable On and Off delays on alarm relays. |
Event logging |
Records alarm, fault and maintenance events. Events can be viewed on-screen and downloaded to a PC. |
Operating temperature |
-40°C to +75°C (-40°F to +167°F)†
|
Humidity |
0 to 95% RH non-condensing† |
Repeatability |
+/- 2% FSD |
Zero drift |
+/- 2% FSD per year maximum |
Response time |
Sensor dependant: contact Crowcon for specific sensor data. |
Approvals |
ATEX and IECEx:
Ex II 2 G Ex db ia IIC T4 Gb (-40 to +75°C) |
Performance |
Designed for compliance with:
EN60079-29-1 (flammable gas sensors)*
EN50104 (oxygen sensors)*
EN45544 (toxic gas sensors)* |
Functional safety |
IEC61508, EN50402 SIL 2* |
EMC Compliance |
EN50270:2015
FCC CFR47 Part 15B
ICES-003 |
† Note: sensor operating temperature and humidity limits vary widely. Contact Crowcon for specific sensor data.
* Features outstanding at the time of issue, contact Crowcon for details.
Gas |
Units |
Max
Range |
Standard
Range |
Alarm 1
level |
Alarm 2
level |
Temp
range °C
|
Oxygen (O2) |
%Vol |
30 |
25 |
19 (falling) |
17 (falling) |
-20 to +50 |
Ammonia |
PPM |
100/1000 |
50 |
25 |
35 |
-20 to +40 |
Carbon Monoxide (CO) |
PPM |
1000 |
250 |
30 |
200 |
-30 to +50 |
Hydrogen Fluoride (HF) |
PPM |
10 |
10 |
1.8 |
3 |
+5 to +40 |
Hydrogen Sulphide (H2S) |
PPM |
100/200 |
25 |
5 |
10 |
-30 to +50 |
Mercaptan (CH3SH) |
PPM |
14 |
14 |
5 |
10 |
-10 to +40 |
Ozone (O3) |
PPM |
1 |
1 |
0.1 |
0.2 |
-20 to +40 |
Sulphur Dioxide (SO2) |
PPM |
100 |
10 |
1 |
1 |
-30 to +50 |
Ethanol (C2H6O) |
%LEL |
100 |
100 |
20 |
40 |
+10 to +75 |
Hydrogen (H2) |
%LEL |
100 |
100 |
20 |
40 |
-40 to +75 |
LPG |
%LEL |
100 |
100 |
20 |
40 |
-40 to +75 |
Methane (CH4) |
%LEL |
100 |
100 |
20 |
40 |
-40 to +75 |
Pentane (C5H12) |
%LEL |
100 |
100 |
20 |
40 |
-40 to +75 |
Propane (C3H8) |
%LEL |
100 |
100 |
20 |
40 |
-40 to +75 |
Ethanol (IR sensor) |
%LEL |
100 |
100 |
20 |
40 |
-40 to +65 |
LPG (IR sensor) |
%LEL |
100 |
100 |
20 |
40 |
-20 to +55 |
Methane (IR sensor) |
%LEL |
100 |
100 |
20 |
40 |
-20 to +55 |
Propane (IR sensor) |
%LEL |
100 |
100 |
20 |
40 |
+10 to + 55 |
Download Catalogue